tempctrl
Displays temperature control parameters
tempctrl
Description
Displays temperature control parameters.
Command
Examples
Field details
| Field | Notes |
|---|---|
ChipDangerous | The threshold on chip temperature in which luxminer will shutdown to prevent hardware damage due to high temperatures. |
ChipHot | The threshold on chip temperature where the miner is considered hot. |
ChipTarget | The target chip die temperature. The default is machine-dependent (see limits). |
Dangerous | The threshold on board temperature in which luxminer will shutdown to prevent hardware damage due to high temperatures. |
Hot | The threshold on board temperature where the miner is considered hot. |
Mode | Either Automatic (luxminer will adjust the fan speed by itself) or Manual (user-provided value). |
Target | The threshold in which luxminer will set fans to 100% to reduce the temperature. |
WaterInletDangerous | The threshold water temperature in which luxminer will shutdown to prevent hardware damage due to high temperatures. |
WaterInletHot | The threshold water temperature above which the inlet is considered hot, used by ATM water inlet protection. |